HHD Electromagnetic Flow Meter

HHD Electromagnetic Flow Meter
Product Detailed
Electromagnetic Flow Meter is a kind of inductional instrument designed by Faradayaas law of electromagn-etic induction to measu

FEATURES:

 1):Simple structures, firm, no movable parts and long operation life  

 2):No intercepting fluid parts, no pressure loss and fluid clogging

 3):No mechanical inertia, quick response and good stability, application in automatic

     examination, adjustment and controlling

 4):Measuring accuracy not influenced by physical parameters such as style, temperature,

      viscosity, density and pressure.

 5):Employ Teflon or rubber liner and different combination of electrode material such as

      Hastelloy C, Hastelloy B, 316L, Titanium and adapt the need of different mediums.

 6):Supply many styles of flow meters such as inline type and insertion type, etc.

 7):Adopt EEPROM memory to measure operation data, safe and reliable protection of

      memory.

 8):Integral type flow meters and remote type flow meters.

 9):LCD back light display with high clearness  

 

TECHNICAL DATA:

       

                                   

Suitable Diameter

DN25~DN2600(below DN25 unstandard)

Electrodes Materials

316L(stainless steel), HC, HB, Ti, Ta

Suitable Fluid

Liquid with conductive ratio more than 5 μs/cm

Measuring Range

0.1~10m/s (extendable to 15m/s)

Upper Limit of Span

0.5~10m/s. 1~5m/s recommended

Accuracy

0.3, 0.5 ,1.0

Output Signals

4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width. high terminal and effective frequency output , RS485 interface

Operation Pressure

1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)

Fluid Temperature

-20C~80C, 80C~130C,130C~180C Depending on Lining Material

Ambient Temperature

Sensor -40C~80C. transducer -15C~50C

Ambient Humidity

<= 85%RH (at 20C)

Cable Outlet Size

M20×1.5

Power Supply

220VAC±10%, 50Hz±1Hz, 24VDC±10%

Power Consumption

<=8W

Protection Ratings

Integral type: IP65. remote type: sensor IP68,transducer IP65

Materials of Liner

PTFE, soft rubber, hard rubber, etc

Connection of Flange

National Standard GB9119-88(DIN2051,BS4504)

Earthing Materials

1Cr18Ni9Ti (stainless steel), HC, Ti, Ta, Cu

  

HHD Electromagnetic Flow Meter